Saturday, June 9, 2012

which is much brighter than fluorescent lamp and better than most similar lighting products

300*1200mm LED panel light

With less light attenuation and a long life span of 50,000 hours, the light can replace T5 fluorescent lamp,which is much brighter than fluorescent lamp and better than most similar lighting products.

Features:

1. Energy saved up to 50% .High brightness.Even lighting output.

2. 5-year life time.

3. Wide range of input voltage: AC 100-240V.

4. Instant start,no flickering,no humming.

5. New high efficiency constant current driver.

6. Special circuit design,each group of LEDs work separately, avoiding any problem of lighting output caused or influenced by single faulty LED.

7. No electrical wave,conforming to CE.

8. Green environmental protection,lead-free material,conforming to RoHS.

9. No RF interference.

Applications:

*Conference/Meeting rooms
*Hotels
*Factories& Offices
*Commercial Purposes
*Residential&Institution Buildings
*Schools,Colleges&Universities
*Hospitals
*Places where energy saving and high color rendering index lightings required.



MAIN SPECIFICATIONS (T=20℃)
NUMBER
ITEM
DESCRIPTION
01
Input Voltage
AC100-240V 50~60Hz
02
Power Consumption
74W /42W(RGB)
03
Luminous Flux
>3900Lm (cool white)   
>2850Lm (warm white)   
04
Color
Warm White /Natural White / Cool White/Red/Green/Blue/Yellow /Orange / RGB 
05
Color Temperature
2700-3300K (Warm White) 
4000-5000K (Natural White) 
5300-7000K (Cool White) 
06
Life Time
>50,000 Hour
07
Operating Temperature
-10℃ to +40℃
08
Storage Temperature
-20℃ to +60℃
09
Humidity operating
10-80%
10
Humidity storage
10-80%
11
Luminosity
>1260Lux ( cool white)
>1025Lux (warm white)
12
Certifications
CE, RoHS
13
Weight
6.5KG
14
Size
298×1198×14mm
15
IK Code
IK04
16
IP Code
IP41
17
Luminaires Class
Class II
18
Fixing Ways
In-built; Mounting;Suspending



Light distribution graph:


Illumination intensity chart:

LED Lumen Attenuation:



Operating time(hours)
Lumen decrease(%)
5,000
2.4
10,000
5.2
20,000
11.3
50,000
24.5



Demensions:

Notes:

1. All dimension units are milimeters.
2. All dimension tolerance is +/- 0.5mm unless otherwise noted.

Packing:

Inner carton: 1285*385*65mm (1 pcs/ctn)
Outer carton: 1300*400*155mm (2 pcs/ctn)
Net weight of each piece: 6.5kg
Quantity: 2 pcs/ctn

Safety notice for using:

1. Please always use the light out of its package.

2. Before starting use of the light,please check if the light was damaged during transportation.If any damage shown,please Do not install or use it.

3.Any maintenance should be performed by trained professional only.

4. Keep packaging materials away from the reach of children and pets.Risks of suffocation!

5. Caution: The packaging contains small parts that may be swallowed by children.

6. Never leave childern unattended in the vicinity of the lights and do not allow them to play with electrical devices.

7. Try to avoid looking directly in the LED beam-especially for extended periods of time.Do not shine the LED light in another person's eyes.

8. Never cover the light by other objectts.

9. The products need to re-pair,inspection or special treatment of retirement after service time.

Maintenance:

1. Prior to cleaning the light,make sure it has been disconnected from the power supply.

2. Use a dry or slightly moistened cloth for cleaning.

3. Never use any chemicals or abrasives for cleaning.

Proposal:

Used electronic devices must be collected for recycling and can not be deposited together with daily garbage.

Installation:

1. This product should be installed by trained electricians.

2. Check  integrality of the products when unpack the packing.

3. The distance between the light and any flammable materials must not be less than 0.2m.The distance between the upper part of the installed light and the ceilling must not be less than 5 cm. The light must not be installed into ceilings or walls that contain heat-insulating material.The main cable must not connect with the low voltage cable or the surface-mounted lights with the pre-fitted clips.Make sure that that these are securely connected to the base material.

4. When laying the cables,make sure that the cables and plugs are not subjected to any tensile or twisting forces.Fit the cable tension relieving mechanisms to the connection points of the surface-mounted lights.Do not kink cable.Output cables should be laid separately and at a distance from other cables.

5. After installation,connect the transformer to the mains supply.

6. Proceed by connecting the wiring cables to the luminaries.Usually,the brown(or black) wire is the ive wire,connect it with the terminal marked "L".The blue wire is Naughty wire,connect it with the terminal marked"N".

7. Used only the LED driver included,and do not connect the surface-mounted lights to other loads.

8. Do not remove the name plate of the power supply and driver of the light.

Notes:

Non-professionals are not allowed to disassemble and maintain the products.We have the right not to provide after-sales service if unauthorized disassembly and maintenance happens to the products.

Any comments, please feel free to contact Amber Zhu: amberzhu0915@gmail.com or call Amber Zhu: +86  18948177087 ,or add Amber Zhu's skype account: amber.zhu88



No comments: